Flush-mounted exhaust unit: discreet and non-intrusive

Humidity sensitive, presence detector and switch versions: modulates the airflow according to the various needs of the dwelling

Advanced special versions: CO2, VOC, and remote control versions

Silent working: silent auxiliary airflow activation

Battery indicator: buzzer to indicate low battery level

Easy to maintain: removable shutter case and front cover for easy cleaning

Description
Characteristics
Schematic
Accessories
Gallery
Videos
Documents

Airflow ‘+’

Airflow can be set at time of installation to meet specific needs, or to compensate for a lack of pressure. The fixed shutter can be set to 6 positions, with an average step of +10 m3/h (maximum = +50 m3/h). It allows the airflow to be adjusted according to the available pressure or specific requirements.

Pressure plug to help commissioning

The built-in pressure plug makes it easy to measure the pressure using a manometer, then calculate airflow using a table in the installation instructions.

Advanced special versions

The BXC was the first exhaust unit in the world offering the possibility of having built-in CO2 and VOC sensors, for example. In keeping the same innovations, the BXC-EG is especially well suited to applications in schools, offices, gymnasiums etc.

Flush-mounted exhaust unit   BXC-EG h BXC-EG p BXC-EG hi BXC-EG hpd BXC-EG pd BXC-EG hps BXC-EG co2 BXC-EG voc
Standard code (other versions available, please contact us)   BXE1999 BXE2012 BXE2005 BXE2003 BXE2010 BXE2035 Contact us Contact us
Airflow                  
Humidity sensitive   ■ – ■ ■ – ■ – –
Boost airflow   ■ ■ ■ ■ ■ ■ ■ ■
Boost airflow activated by switch   – – ■ – – – – –
Boost airflow activated by presence detection   – ■ – ■ ■ – – –
Other activation modes               CO2 level VOC level
Airflow @ 100 Pa (min.-max.) (1) (2) m3/h 12-80
Airflow ’+’ – maximum available airflow @ 100 Pa (3) m3/h 130
Acoustics                  
Sound power level Lw(A), 100 Pa, RH = 65 %, minimum. airflow ‘+’ setting dB(A) 26 (+/- 1)
Dn,e,w (C, Ctr) Acoustic insulation, RH = 65 %, min. airflow ‘+’ setting dB 58 (-2 ;-3)
Power supply                  
2 x 1.5 V AAA LR03 batteries (not supplied)   – ⊗ ⊗ ⊗ ⊗ ⊗ ■ ■
Buzzer (low battery charge)   – ■ ■ ■ ■ ■ ■ ■
12 VAC supply with specific transformer (ref. CAL261)   – ⊗ ⊗ ⊗ ⊗ ⊗ ■ (CAL included) ■ (CAL included)
230 VAC supply with specific transformer (ref. CAL1228)   – ⊗ ⊗ ⊗ ⊗ ⊗ ■ (option) ■ (option)
Characteristics                  
Colour   white
Material (main)   PS / ABS
Installation                  
Round duct compatibility with integrated spigot mm ø100
Round duct compatibility with integrated spigot with integrated 90° elbow ferrule ø100 (4) mm ■ ■ ■ ■ ■ ■ ■ ■
Round duct compatibility with accessory spigot (5) mm ø125
Round duct compatibility with 85343AL accessories mm ø80
Other functions                  
Pressure plug   ■ ■ ■ ■ ■ ■ ■ ■
Fault indicator thanks to a built-in pressure sensor   – – – – – ■ – –

 

■ : standard / included  ⊗ : compatible

Note: airflow given for a ø100 duct
(1) Default setting.
(2) Tolerance : 13m3/h +/- 3  ,  80m3/h +/- 10.
(3) Airflow ‘+’: the airflow can be increased from +10 m3/h to +50 m3/h (6 positions available). This function can be used to adapt to lower pressure or to specific regulations imposing higher airflows. Standard is position 0 (minimum airflow = 12 m3/h @ 100 Pa).
(4) Delivered in specific version.
(5) Delivered in specific versions or available as accessory (ref. AEA317).
Other versions available, please contact us.

AIRFLOW / DIMENSIONS IN MM

Aereco BXC-EG Elbow

IMAGE CODE DESIGNATION
CAF CAF Stops the propagation of fire cold smokes through ventilation ducts
CAL261 CAL261 Supply device 12 VAC / 3 VDC (mandatory for BXC connected to 12 VAC supply)
CAL1228 CAL1228 Supply device 230 VAC / 3 VDC (mandatory for BXC connected to 230 VAC supply)
33007AL 33007AL Trident plastic sleeve ø125 mm – L 125 mm
85343AL 85343AL Trident plastic sleeve ø125 mm – ø80 mm – L 125 mm
19429AL 19429AL Phonic ring for exhaust units – ø125 mm
AEA317 AEA317 Plastic adapter ø125 mm, black, with joint
AEA478 Remote control for boost airflox activation

The BXC-EG: a flush-mounted exhaust unit for assured discretion

 

BXC-EG flush-mounted exhaust unit installation

BXC-EG

Product booklet - FLY739GB_v3 

BXC-EG

Maintenance instruction - D7282_B

BXC-EG

Installation instruction - D7281_B

Compatible ventilation systems: